SPECIFICATIONS

MASONRY WALL

L01 Common brickwork/blockwork texture rendered finish with insulation to meet building code of australia – basix / energy efficiency

L02 Concrete masonry wall (design by engineer)

L03 Low wall @1500mm high common brickwork texture rendered finish

L04 190mm thk blockwork with texture render finish provide insulation to meet building code of australia – basix / energy efficiency

L05 Select stone wall cladding on common brick / blockwork -provide insulation to meet building code of australia – basix / energy efficiency

L06 160mm thick precast concrete curved wall to manufacturer’s specifications

L07 Framed feature wall cladding mdf – wallpaper over

L08 Fire separating wall concrete blockwork frl 60 / 60 / 60  (no penetrations) (see detail  2 / wd-07)

L09 Retaining wall (to engineer’s design)

L10 Hardiplank smooth cladding – provide insulation to meet building code of australia – basix / energy efficiency

L11 Select stone finish retaining wall (to engineer’s design)

L12 Select limestone installed as per manufacturer’s specifications supply insulation to meet building code of australia – basix / energy efficiency

L13 300mm x 600mm himalayan chipped cladding over common brickwork/blockwork supply insulation to meet building code of australia – basix / energy efficiency

L14 Boral partiwall 90/90/90 to manufacturer’s specifications to meet  building code of australia

L15 Full height 900mm clay brickwork 60 / 60 / 60 fire rating with rw + ctr of 50 non combustible sarkin below flashing /  roof fix to meet building code of australia

L16 Select face brickwork finish with insulation to meet building code of australia-basix/energy efficiency

L17 Hebel block wall texture rendered finish provide with insulation to meet building code of australia – basix / energy efficiency

L18 Steel wall sheeting – galvanized finish

L19 2000 tall x 230 x 1400 wide common brick / blockwork feature wall with texture render finish

L20 Brickwork / blockwork wall 2000mm high x 230 mm thk with lime stone finish on dark grey rustic horizontal lines – see detail

L21 70 mm wide timber framed dwarf wall with powder coated aluminum handrail over in accordance with the building code of australia note – foam board exterior cladding with texture render finish over (hardiflex lining to internal – providing bracing to wall)

L22 2100 mm low partition wall

LIGHTWEIGHT WALL / CLADDING

Lw01 40mm thk foam board with texture render finish supply insulation to meet building code of australia – basix / energy efficiency

Lw02 Hardiflex wall cladding with timber battens supply insulation to walls to meet building code of australia- basix / energy efficiency (refer to manufacturer’s specification)

Lw03 Hardiflex wall cladding supply insulation to walls to meet building code of australia – basix / energy efficiency(refer to manufacturer’s specification)

Lw04 Weathertex fc sheeting eco groove woodsman 300mm wide – painted finish. Provide insulation to meet building code of australia – basix / energy efficiency

Lw05 Linea weather board exterior cladding – provide insulation to meet building code of australia – basix / energy efficiency

Lw06 Alpolic cladding fixed as per manufacturer’s specifications (see details)

Lw07 Axon scyon cladding fixed as per manufacturer’s specifications supply  insulation to meet building code of australia – basix / energy efficiency

Lw08 Blueboard cladding with texture rendered finish fixed as per manufacturer’s specifications supply  insulation to meet building code of australia – basix / energy efficiency

Lw09 Fc sheeting with random timber strip finish as shown

Lw10 Colorbond mini orb cladding on common brick/blockwork – supply insulation to meet building code of australia – basix / energy efficiency

Lw11 Colorbond metallic steel cladding provide insulation to meet building code of australia – basix / energy efficiency

Lw12 Select copper panel cladding supply insulation to walls to meet building code of australia – basix / energy efficiency (refer to manufacturer’s specification)

Lw13 Sycon matrix board with express joint provide insulation to meet building code  of australia – basix / energy efficiency

Lw14 Hardie plank smooth type provide insulation to meet building code of australia – basix / energy efficiency

Lw15 Select cedar exterior cladding – provide insulation to meet building code of australia – basix / energy efficiency

Lw16 Scyon stria cladding provide 40mm thk foam board with texture render finish supply insulation to meet building code of australia- basix / energy efficiency

FLOOR FINISHES

Ff01 Select treated hardwood timber steps

Ff02 600mm x 600mm tiled hardstand (to owner select)

Ff03 Select 600mm x 600mm floor tiles (provide fall away from building) with waterproofing membrane applied as per manufacturer’s specifications

Ff04 Select non-slip tiles flooring over 15mm thk compressed fc sheeting with “pabco” juteal (or similar) waterproof membrane tile finish (provide fall away from building)

Note:       compressed fc sheeting fixing in accordance with manufacturer’s specifications

Ff05 90mm x 19mm hardwood decking over 15mm thk compressed fc sheeting (or similar)  waterproof membrane (provide fall away from building) note: compressed fc sheeting fixing in accordance with manufacturer’s specifications

Ff06 Floor joist to engineer’s/ manufacturer’s specification & in accordance with a.s. 1720 (1988) @ 450 crs with select 90mm x 19mm treated hardwoodtimber decking over

Ff07 Rip rap (to engineer’s design)

Ff08 150mm raised timber flooring

Ff09 Select non-slip floor tiles (provide fall away from building) supply waterproofing membrane as per manufacturer’s specifications

Ff10 90mm x 19mm hardwood timber decking provide fall away from building fixed as per a.s. 3660 – 2000

GUTTER/ FLASHING/ DP

G01 2400 x 3100 wide sectional overhead grille type door w/ auto

G02 2400 x 4800 wide sectional overhead  door w/ auto

G03 2400 x 2400 wide sectional overhead  door w/ auto

G04 Select aluminum louvre type garage door

G05 Select smoothline 2400 x 4800 wide  light sectional steel overhead door with auto

G06 2100 x 3100 wide sectional overhead  grille type door w/ auto

G07 2100 x 4800 wide sectional overhead  door w/ auto

HOODS

H01 Wrapped around hood 300mm depth

H02 Select aluminum sunshading louvres

H03 Nrg green board sunhood with texture render finish fixed as per manufacturer’s specifications (see details

 

ROOFING

R01 Colorbond roofing with insulation to meet building code of australia and basix / energy efficiency requirement

R02 Select concrete roof tiles provide insulation to meet building code of australia and basix / energy efficiency requirement

R03 Colorbond (lysaght klip-lok) roofing with insulation to meet building code of australia and basix / energy efficiency requirement

R04 Select concrete flat tiles provide insulation to meet building code of australia and basix / energy efficiency requirement

R05 15mm thk bcg compressed fibre cement sheeting with waterproofing membrane to all joints (i.e. “paco” juteal or similar as per manufacturer’s specifications) provide fall away from building

R06 Tempered glass roofing fixed as per manufacturer’s specifications

R07 Provide 300∅ skydome – to manufacturer’s specifications

R08 Canopy with tempered glass roofing – see detail

R09 Solar panels installed as per manufacturer’s specifications

R10 Aluminum sheet covering

R11 Resin coated fiber glass reinforced polysterene fix as per manufacturer’s specification to meet the building code of australia

R12 Custom orb roofing with double sided aluminum foil 150mm thk mineral wool blanket under to meet building code of australia and- basix / energy efficiency requirement

R13 Select dampalon polycarbonyte flat type roofing with free span rafter system fixed as per manufacturer’s specification

R14 Vergola opening roof system fixed as per manufacturer’s specifications

R15 Select aluminum sheet covering at the edge

Of the roof

R16 Existing parapet to be replaced with new colorbond fascia and gutters to existing roof fixed as per manufacturer’s specifications

R17 Prefab fascia and gutter – to manufacturer’s specifications

R18 Select terracotta roof shingles flat type – provide insulation to meet building code of australia – basix / energy efficiency requirement

R19 Roof pitch same as existing

R20 Pinnacle

R21 200mm x 50mm overflow to box gutter

R22 Colorbond roofing with double sided aluminum foil / 50mm thk material wool blanket under to meet building code of australia – basix / energy efficiency requirement

R23 Roof pitch

CEILING

CL01 Plasterboard ceiling and walls – supply insulation to meet Building Code of Australia- Basix / Energy Efficiency

CL02 ___mm drop ceiling line

CL03 Plasterboard ceiling on 22mm furring channel

CL04 Drop ceiling with concealed lighting

CL05 Villaboard soffit lining – supply insulation to meet Building Code of Australia- Basix / Energy Efficiency

CL06 T & G timber ceiling

CL07 Plasterboard ceiling and walls – supply insulation to meet Building Code of Australia- Basix / Energy Efficiency

CL08 Luxalon sun louvers or similar with tempered glass roof over installed as per manufacturer’s specifications

CL09 Luxalon 150f aluminium linear ceiling (off-white color) or similar – installed as per manufacturer’s specifications

 

ROOF STRUCTURE

Rs01 250 ub 31 steel roof truss (to engineer’s design)

Rs02 Roof framing to engineer’s design

Rs03 45° standing solar panel fixed as per manufacturer’s specs

Rs04 Roof trusses to engineer’s /manufacturer’s drawing & specification

Rs05 Concrete roof and beams to engineer’s design and specifications provide water proofing membrane to meet building code of australia

Rs06250 ub 31 steel  roof truss (to engineer’s design)

Rs07 Decorative roof trusses on raked ceiling -to manufacturer’s specifications

Rs08 50mm x 150 mm aluminum trellis see manufacturers specification

Rs09 C-chanel (to engineer’s design)

Rs10 100mm x 200mm timber rafters spaced @___ equal parts over ceiling or __ mm distance of spacing

Rs11 50mm x 250mm main rafters

Rs12 50mm x 250mm timber truss members

Rs13 100mm x 250mm timber beam

FLOOR STRUCTURE

Fs01 Post tensioned slab (design by engineer)

Fs02 90mm x 19mm hardwood decking bridge with steel beam to engineer’s detail

Fs03 Floor joist system -to manufacturer’s specifications and in accordance with a.s.  1720.1 (1988) @ 450 crs with 19mm sheet flooring over

Fs04 Steel floor joist to manufacturer’s specifications

Fs05 Timber floor joist to engineer’s design & specifications

Fs06 Concrete slab and beams to engineer’s design and specifications

Fs07 Concrete footing and slab (to engineer’s design)

Fs08 250mm thk steel i-beam frame (to engineer’s design)

CABINET/NICHE

C01 Refer to owner’s shelving detail

C02 Refer to owner’s kitchen detail

C03 300mm x 300mm soap holder niche

C04 2110 niche 300mm fr. Floor

C05 Bookshelves panel system refer to owners bookshelves design

C06 Bar counter (refer to owner’s design)

C07 Cellar cabinetry (refer to owner’s design)

C08 Cabinet counter with shelving above to owner shelves design

C09 300mm x ____mm niche 1200mm high from floor

C10 Canopy rangehood over

C11 1300mm x 800mm plasma niche 1000mm from ffl

C12 600mm x 1500mm niche 1200mm high from floor

C13 Refer to owner’s cabinetry detail

C14 Shelf over ref. @ 1800mm high

C14 1300mm x 800mm Plasma niche 1000mm from FFL

 POST/COLUMN

P01 230mm x 230mm timber framed post

P02 ______ shs post to engineer’s design

P03 Sheet timber log columns

P04 200mm x 200mm timber cladded post

P05 00mmø metal post

P06 100mm x 100mm shs silver anodized post

P07 Select stone cladding on blockwork post to engineer’s design

P08 ____mm x ____mm  brickwork/ blockwork piers with texture render finish (to engineer’s design)

P09 200mm x 200mm shs posts bolt fixed to  concrete floor

P10 90mm x 90mm shs post bolt fixed to blockwork pier (to engineer’s detail and design)

P11 Select stone cladding on blockwork post design by engineer

P12 3000mm high (above entry slab level) brickwork / blockwork column with feature stack stone finish over note – 90mm x 90mm shs post bolt fied to column supporting entry roof above

P13 Brickwork feature piers with stack stone finish over

P14 90mm x 90mm / 120mm x 120mm / 150mm x 150mm timber post

P15 250mmø timber log columns

P16 90mm x 150mm diagonal timber bracing

P17 200mmø metal post

P18 250mm x 250mm timber framed posts

P19 Typical decorative timber supports – see details

P20 Classical lightweight concrete new columns – as per manufacturer’s specifications

P21 400mm x 400mm blockwork brickwork concrete pedestal rendered finish

P22 150mmø chs post (to engineer’s design

BALUSTRADE/RAILING

B01 1000mm high semi-frameless glass balustrade w/ s.s. grab rail installed as per manufacturer’s specifications to meet building code of australia

B02 Blockwork dwarf balustrade

B03 Select aluminum balustrade on balcony installed as per manufacturer’s specifications to meet building code of australia

B04 1000mm high frameless glass balustrade w/ s.s. grab rail on juliet balcony installed as per manufacturer’s specifications to meet building code of australia

B05 1000mm high flat bar steel balustrade installed as per manufacturer’s specifications to meet building code of australia

B06 Stainless wire balustrade fixed as per manufacturer’s specifications to meet building code of australia

B07 Galvanised steel balustrading.

B08 Semi-frameless glass balustrade on stairs @ 1000mm high

B09 Select timber balustrade

B10 Frameless glass balustrade – select oval stainless steel handrail installed as per manufacturer’s specifications to meet building code of australia

B11 Select 1000mm high railing powder coated aluminum french type fixed as per manufacturer’s specification to meet building code of australia

B12 Select 1800mm high glass panel to toilet & shower area

B13 1000mm high frameless off-stand glass balustrade w/ grab rail installed as per building code of australia

B14 Select oval type aluminum handrail with s.s. wire balustrade as per manufacturer’s specifications to meet building code of australia

B15 Select aluminum railing on stairs installed as per manufacturer’s specifications to meet building code of australia

B16 Select steel deck railing – to manufacturer’s specification

B17 Select powder coated aluminium frame glass balustrade

B18 Flat plate steel balustrade paint finish

B19 Glass handrail / screen  over from 1000mm above fl

B20 1200mm high flat bar steel balustrade installed as per manufacturer’s specifications

B21  Powder coated aluminium handrail over dwarf wall in accordance with building code of australia

B22 1000mm high semi-frameless glass balustrade with anodized handrail on balcony installed as per manufacturer’s specifications

GARAGE DOOR

Gd01 2400 x 3100 wide sectional overhead grille type door w/ auto

Gd02 2400 x 4800 wide sectional overhead  door w/ auto

Gd03 2400 x 2400 wide sectional overhead  door w/ auto

Gd04 Select aluminum louvre type garage door

Gd05 Select smoothline 2400 x 4800 wide  light sectional steel overhead door with auto

Gd06 2100 x 3100 wide sectional overhead  grille type door w/ auto

Gd07 2100 x 4800 wide sectional overhead  door w/ auto

DOOR

D01 Select timber false shutter door

D02 _____ x _____ semi-cavity door

D03 _____ x _____ cavity door

D04 1500mm x 2100mm solid pivot door installed as per manufacturer’s specifications

D05 Stacker doors powder coated aluminum frame to manufacturer’s specifications

D06 Timber false shutter door

D07 2400mm x 1200mm pivot door (xs24 savoy hume door)

D08 Glass door

D09 Select timber bifold door (customized)

D10 Select timber cavity door

D11 Select timber sliding door

D12 Select timber frame glass

D13 Select decorative with floral pattern hardwood door

D14 Select csd plantation louver

D15 Select timber plantation type door

D16 Hinge door melamine shelves within

SWIMMING POOL & POOL FENCING

Sp01 1200mm high semi-frameless glass pool fence installed as per manufacturer’s specification

Sp02 1200mm high pool fence door fitted with self latching device & auto return

Sp03 1200mm high frameless glass pool fence installed as per  manufacturer’s specification

Sp04 Pool pump motor room w/ powder coated aluminum slatted door

Sp05 Pool structure (to engineer’s design)

Sp06 Pool pump motor room w/ powder coated aluminum slatted door

WINDOW

W01 _____mm high fixed glass window above main door

W02 _____mm high fixed glass window above

W03 Select glass louver windows

W04 Fixed glazing installed as  per manufacturer’s specifications

W05 Clear glass awning  windows as per manufacturer’s specifications

W06 Fixed frosted glass feature window _____mm high from ffl

W07 Tempered glass on aluminum frame (to manufacturer’s detail)

W08 Glass louver window

W09 _____mm high fixed glazing

W10 _____mm high window above wall

W11 Select glass block

W12 Fixed splashback glazing fixed as per manufacturer’s specifications

W13 50mm x 190mm timber mullion

FENCE

F01 1800mm high brickwork / blockwork fence wall with select stone cladding

F02 1800mm high select colorbondpowder coated aluminum fence door

F03 190mm thk retaining wall 300mm high from driveway (to engineer’s design)

F04 Select 1800 mm high approved aluminum fence installed as per manufacturer’s specifications

F05 Brickwork fence 2000mm high x 190mm thk texture render finish or similar type of fence with vertical groove 3000mm o.c.

F06 Existing perimeter fence

F07 1800mm high lapped and capped timber fencing

F08 Brickwork fence 1800 mm high texture render finish or similar type of fence

F09 Rendered blockwork/brickwork fence 1800mm high

F10 1800mm hebel system fencing wall

F11 1800mm high tilt panel concrete fencing

F12 1800mm high timber paling fencing

F13 Select 1800mm high aluminum linear fencing

F14 1800mm high aluminum linear gate

F15 1800mm high lapped & capped timber fencing & gate installed per manufacturer’s specifications

F16 Fixed glass on anodized aluminium as per manufacturer’s specifications

F17 Select approved aluminium fence installed as per manufacturer’s specifications

F18 1800mmselect aluminium open type fencing

SCREEN & LOUVERS

Sl01 Select aluminum linear screen

Sl02 Aluminum slatted sun screen fixed to manufacturer’s specifications

Sl03 Luxalon aerobrise 70mm sunscreen louver

As per manufacturer’s specifications

Sl04 Select powder coated interior aluminum shutter

Sl05 Aeroblades i-frame & supports (to engineer’s design)

Sl06 Aeroblades installed as per manufacturer’s specification

Sl07 Select powder coated slatted aluminum screen fixed as per manufacturer’s specification

Sl08 Hardwood timber screens – clear finish-randomly spaced

Sl09 Select timber 30mm x 30mm horizontal slats screen

Sl10 Select exhaust hood fixed as per manufacturer’s specifications

Sl11 Select trellis installed as per manufacturer’s specifications

Sl12 Select flashing fixed  as per manufacturer’s specifications

Sl13 Select timber louvre window

Sl14 Steel i-beam canopy frame with luxalon on sunscreen louver as per manufacturer’s specification

Sl15 Luxalon 150mm aerobrise sun filter or similar fixed as per manufacturer’s specification

Sl16 Select fixed fly screen

Sl17 Select powder coated aluminum privacy Screen as per manufacturer’s specifications

SECTION

S01 Location of underground water tank

S02 150mmø s.s. pipe to discharge to storm line

S03 Line of existing contour on tbc site

S04 Footing and slab (to engineer’s design)

S05 Compacted granular backfill

S06 90mm agg with pea gravel surround, free discharge to stormwater

S07 Footing and reataining wall (to engineer’s design)

S08 Waterproof membrane

S09 Provide 50mm ∅ water pipe

S10 Fc soffit lining

STAIRS

S01 Concrete stairs (to engineer’s design)

S02 Select stainless steel railing fixed as per manufacturer’s specifications

S03 50mm  aluminum handrail on 1000mm high semi-frameless glass balustrade on balcony installed as per manufacturer’s specifications

S04 Steel supported open tread stairs to manufacturer’s specification

S05 Select hardwood timber steps

S06 Open tread timber stairs on steel  stringer w/ frameless glass handrail 1000mm above fl

S07 Open tread timber stairs with single spine stringer installed as per manufacturer’s specifications

S08 Cantilever stair w/ joinery under

S09 Select timber closed type stair railing – to manufacturer’s specifications

S10 Frameless clear glass stair balustrade w/ handrail – installed as per manufacturer’s specifications

S11 Tiled steps

S12 Fixed glass screen from ceiling to face of treads from height above floor level requiring handrail as stated in the building code of australia

S13 Closed tread timber stair with semi frameless glass balustrade fixed  As per manufacturer’s specification

S14 Closed tread timber stair with  stainless steel grab rail fixed  As per manufacturer’s specification

WINDOW SHUTTER/ SCREEN

W01 Select timber shutter window

W02 Select powder coated aluminum screen fixed as per manufacturer’s specifications and supply insulation to meet building code of australia – basix / energy efficiency

W03 Select timber louvre shutters as per manufacturer’s specifications

W04 Select timber shutter

W05 Select bi-fold aluminum shutter

W06 Select fixed aluminum sunscreen

W07 Select aluminum louver screen

W08 Select timber louver shutter fixed as per manufacturer’s specifications

W09 Select 2100mm x 300mm louver ventilation – to manufacturer’s specifications

W10 Fixed louver window

SKYLIGHT/ LOUVRE/ SOLAR PANEL

Sk01 Skydome  skylight fixed as per manufacturer’s specification

Sk02 Skydome or similar flat type skylight with ____mm  luxalon louver sunscreen  on ceiling line both fixed as per manufacturer’s specification

Sk03 Skydome  skylight with exhaust fan fixed as per manufacturer’s specification

Sk04 Skylight flat type installed as per manufacturer’s specification

Sk05 Skylight with aluminum sun screen

Sk06 Luxalon aluminum linear ceiling or similar as per manufacturer’s specifications

Sk07 Luxalon 150f aluminum linear ceiling (off-white color) or similar – installed as per manufacturer’s specifications

Sk08 Solar panels installed as per manufacturer’s specifications

SITE PLAN

Sp01 Clothes lining

Sp02 Setout point

Sp03 Area of encroachment

Sp04 Planter

Sp05 Easement line

Sp06 Min. 3000l rain water tank

Sp07 Outside shower

 

ELECTRICAL

E01 Note: on beam

E02 Powerbox location  (tbc on site)

E03 Select wall mounted light

E04 Meter box position (tbc on site)

E05 Intercom

E06 100-200-300m³/hr exhaust fan above with auto

E07 300mm x 300mm exhaust fan above with auto

E08 Provide exhaust fan and light

 

 

GATE

GA02 Powder coated aluminium sliding gate to manufacturer’s specifications

GA03 Select 1800mm high powder coated aluminium sliding gate to manufacturer’s specification

GA05 Select silver anodized slatted aluminium gate door

GA06 Frosted glass on powder coated aluminium fence gate doo

HYDRAULICS

Hy01 Stormwater pit pumps to hydraulic drawings

Hy02 Stormwater  pump control

Hy03 Note: back up diesel generator for storm water pit pump

Hy04 300 sq. Sump drain to hydraulic engineer’s design

Hy05 New gatic drain as per manufacturer’s specification

Hy06 Pvc channel drain

FIREPLACE

Fp01 Flue/vent to firebox installed as per manufacturer’s specifications

Fp02 Real flame double vision gas fireplace

Fp03 Smoke stack

Fp04 Select fire flue – to manufacturer’s specifications

Fp05 Masonry chimney – to engineer’s design

Fp06 Chimney with select stack stone finish

Fp07 Select fireplace – provide flue provision on roof-ceiling installed as per manufacturer’s specifications

Fp08 Select double sided fire place provide flu provision on roof-ceiling installed as per manufacturer’s specifications

ELEVATOR

Elev01 Otis homelite elevator or similar installed as per manufacturer’s specifications

Elev02 Superdomus  elevator or similar installed as per manufacturer’s specifications

Elev03 Refer to lift manufacturer for lift requirement

 

WATER FEATURE

Wf01 Water feature with stack stone finish over

Wf02 Water feature under open stair

Note:  provide waste and waterproofing

Wf03 Select water feature to tie into pool under seperate application

Wf04 All water feature provide waste and water proofing connect

An overflow pipe to storm water

 

RENOVATION

Re01 New doors and windows to replace existing

Re02 Existing steel post to be retained and refurnish

Re03 Existing glazing to be retained

Re04 Existing window to be replaced

Re05 Part of existing concrete slab and footing to be retained

Re06 Part of existing roof above to be retained

Re07 Existing roof above to be replace with select aluminum louver

Re08 Texture render finish on existing brick wall

Re09 Existing concrete retaining wall (t.b.c. on site)

Re10 Existing concrete parapet to be removed

Re11 Existing dwarf wall concrete wall

Re12 Existing feature wall to be repainted

Re13 Texture render finish on existing brick wall

Re14 Existing steel beam to be retained and refurnish refer to structural engineer’s design

Re15 Line of existing steel beam

Re16 Part of existing structure (tbc)

Re17 Existing balustrades to be replaced with new semi-frameless anodized aluminum framed glass balustrade w/ 2″ oval handrail to manufacturer’s specifications -see details

Re18 New fence to match existing

MOULDINGS

M01 Select decorative moulding

M02 Select lightweight concrete moulding

M03 Feature hole

M04ightweight ornamental pinnacle- as per manufacturer’s specifications

 

LANDSCAPING

Ls01Set down with drain for “zen garden” –  pebble finish flush to living

OTHERS

O01 Line of driveway

O02 Garbage bins

O03 ________ liters underground rain water tanks

O04 Select 1800mm high glass panel to toilet & shower area